High quality core cutting line supplier factory: Poor power quality can severely impact the performance of transformer equipment, leading to a variety of negative outcomes. These consequences not only affect the operational efficiency of the equipment but also pose significant economic concerns. One of the primary damages caused by poor PQ is the deterioration of the transformer’s health. Poor PQ, characterized by factors like voltage sags, swells, harmonics, and transients, can cause excessive heating in transformers. This undue heat can degrade the insulation material used in transformers, subsequently reducing their lifespan and potentially leading to catastrophic failures. Therefore, poor power quality can lead to considerable damage to transformer equipment, resulting in economic losses, reduced energy efficiency, and decreased productivity. Therefore, maintaining high power quality is crucial for the optimal performance of transformer equipment and overall operational efficiency. Discover even more information on https://www.canwindg.com/products-detail-127763.
Insulation level: The insulation level of a transformer refers to the insulation performance of the transformer at the time of design. For example, a 220kV transformer means that the designed insulation voltage of the transformer is 220 kV. Cooling method: The cooling method of the transformer refers to the heat dissipation method of the transformer. For example, transformers can dissipate heat through natural cooling, forced air cooling, or forced water cooling. To sum up, the rated value on the transformer nameplate refers to some important electrical parameters and performance indicators of the transformer, which is of great significance for the selection, installation and operation of the transformer.
What is eddy current? What are the disadvantages of eddy current generation? Eddy current refers to a kind of current generated in the conductor, which is the induced current caused by the change of the magnetic field. The eddy current forms a circular current flow path in the conductor, and this current forms a motion state similar to an eddy current inside the conductor, so it is called an eddy current. The generation of eddy currents has the following disadvantages: Energy loss: Eddy currents create circular currents in conductors, which generate heat as they flow continuously in conductors. Since the generation of eddy currents is caused by changes in the magnetic field, in equipment such as transformers and motors.
The trademark “CANWIN” has won the title of the famous trademark of the international electrotechnical association and the trademark CANWIN CNC” has been recognized as a high -end manufacturing brand in China. We has been judged as Guangdong province enterprise that strictly contracts and keeps promises” and won the honor of”excellent supplier of Chinese electrical equipment” successively. The company has a number of national patents, and won the Guangdong provincial department of science and technology major project award the first set of domestic new products award; The company is a key enterprise in the field of electric power electrical equipment manufacturing in China, and a core professional equipment supplier of state grid, China southern power grid and many listed companies in the electric power industry. Its products are exported to countries and regions in Asia, Africa, Latin America, Europe and the United States.
Canwin is a professional ctl line manufacturers & suppliers china, we have been specialized in ctl machines for over 20 years.This cut to length production line adopts advanced control system to ensure the accurate and stable operation of the cut to length production line. Embedded operating terminal can complete parameter setting quickly and conveniently. After the coil material of silicon steel sheet is punched and cut into certain shape and size by this cut to length production line, the classification and finishing work is completed at the end of the production line, and it is automatically stacked into 20 columns and used for the core assembly.
Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.
The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.
The loss in magnetic flux in the transformer must therefore be minimized by providing a suitable mean between the primary and secondary windings. For this purpose, silicon steel magnetic cores are usually used. By using a core type transformer, magnetic losses are reduced and a greater amount of magnetic flux is conveyed between the primary and secondary coils, thereby increasing the transformer’s overall efficiency. Electrical materials play an important role in the field of engineering technology. Various technologies should be realized through certain equipment, and the equipment needs to be made of specific materials. Without corresponding materials, even technologies and products that are feasible in principle cannot be realized. The emergence of new materials can often bring significant technological progress. See additional information at canwindg.com
Transformer application of aluminum foil to make dry type transformer has small volume, light weight, good insulation performance, flame retardant, no pollution, little partial discharge, moisture proof, stable and reliable operation, low noise, low maintenance cost advantages, in the high-rise building, underground facilities, business center, residential, hotels and humid coastal areas and other applications.Want to konw composition of aluminum foil, please contact Canwin, one of the best copper foil suppliers & manufacturers in China, specialized in aluminium copper foil and transformer copper foil for over 20 years. With the rapid development of laser machines technology and equipment, it is more and more widely used in various fields. At present, most hardware products still use argon arc welding and other welding methods in production and processing.
Energy management system, which uniformly allocates and manages the wind energy, photovoltaic, power grid, battery system and distribution system of micro grid, so as to achieve energy efficiency and high-quality energy allocation. The remote cloud platform and mobile terminal can optimize the system through big data analysis, while reversing the relevant information and operation status to the users’ mobile phone. Containerized Energy Storage System is a complete, self-contained battery solution for a large-scale marine energy storage. The batteries and converters, transformer, controls, cooling and auxiliary equipment are pre-assembled in the self-contained unit. Advantages of containerized power systems: customization, scalability, stackable and cost effective.
Impedance voltage (%): Short-circuit the secondary winding of the transformer and slowly increase the voltage on the primary winding. When the short-circuit current of the secondary winding equals the rated value, the voltage applied on the primary side is the impedance voltage. It is usually expressed as a percentage of the rated voltage. Phase number and frequency: Three-phase is represented by S, and single-phase is represented by D. The frequency f of China’s national standard is 50Hz.There are countries abroad with 60Hz (such as the United States).I. Temperature rise and cooling: The difference between the temperature of the transformer winding or upper oil layer and the temperature of the surrounding environment is called the temperature rise of the winding or upper oil layer. The limit value of the temperature rise of the oil-immersed transformer winding is 65K, and the temperature rise of the oil surface is 55K.There are also various cooling methods: oil-immersed self-cooling, forced air cooling, water cooling, tube type, sheet type, etc.